radiative_cooling_init Subroutine

public subroutine radiative_cooling_init(fl)

Uses

  • proc~~radiative_cooling_init~3~~UsesGraph proc~radiative_cooling_init~3 radiative_cooling_init module~mod_global_parameters mod_global_parameters proc~radiative_cooling_init~3->module~mod_global_parameters module~mod_basic_types mod_basic_types module~mod_global_parameters->module~mod_basic_types module~mod_connectivity mod_connectivity module~mod_global_parameters->module~mod_connectivity module~mod_constants mod_constants module~mod_global_parameters->module~mod_constants module~mod_physicaldata mod_physicaldata module~mod_global_parameters->module~mod_physicaldata module~mod_variables mod_variables module~mod_global_parameters->module~mod_variables mpi mpi module~mod_global_parameters->mpi module~mod_variables->module~mod_basic_types

the params require to be read in phys template file phys_init

Arguments

Type IntentOptional Attributes Name
type(rc_fluid), intent(inout) :: fl

Calls

proc~~radiative_cooling_init~3~~CallsGraph proc~radiative_cooling_init~3 radiative_cooling_init proc~findl~3 findL proc~radiative_cooling_init~3->proc~findl~3 proc~mpistop mpistop proc~radiative_cooling_init~3->proc~mpistop mpi_abort mpi_abort proc~mpistop->mpi_abort

Source Code

    subroutine radiative_cooling_init(fl)
      use mod_global_parameters

      type(rc_fluid), intent(inout) :: fl
  
      double precision, dimension(:), allocatable :: t_table
      double precision, dimension(:), allocatable :: L_table
      double precision :: ratt, fact1, fact2, fact3, dL1, dL2
      double precision :: tstep, Lstep
      integer :: ntable, i, j
      logical :: jump

      call rc_params_read(fl)

      ! Init for interpolatable tables
      allocate(fl%tcool(1:fl%ncool), fl%Lcool(1:fl%ncool))
      allocate(fl%Yc(1:fl%ncool))

      fl%tcool(1:fl%ncool)    = zero
      fl%Lcool(1:fl%ncool)    = zero

      ! Read in the selected cooling curve
      select case(fl%coolcurve)
      case('JCcorona')
        if(mype ==0) &
        print *,'Use Colgan & Feldman (2008) cooling curve'
        if(mype ==0) &
        print *,'This version only till 10000 K, beware for floor T treatment'
        ntable = n_JCcorona
        allocate(t_table(1:ntable))
        allocate(L_table(1:ntable))
        t_table(1:ntable) = t_JCcorona(1:n_JCcorona)
        L_table(1:ntable) = l_JCcorona(1:n_JCcorona)

      case('Colgan_DM')
        if(mype==0)&
        print *, 'Combination of Colgan (2008) for high temperatures and'
        if(mype==0)&
        print *, 'Dalgarno & McCray (1972), DM2, for low temperatures'
        ntable = n_Colgan + n_DM_2
        allocate(t_table(1:ntable))
        allocate(L_table(1:ntable))
        t_table(1:n_DM_2) = t_DM_2(1:n_DM_2)
        L_table(1:n_DM_2) = L_DM_2(1:n_DM_2)
        t_table(n_DM_2+1:ntable) = t_Colgan(1:n_Colgan)
        L_table(n_DM_2+1:ntable) = l_Colgan(1:n_Colgan)

      case('TRML_narrow')
        if(mype==0)&
        print *, 'TRML narrow cooling'
        ntable = n_TRML_narrow
        allocate(t_table(1:ntable))
        allocate(L_table(1:ntable))
        t_table(1:ntable) = t_TRML_narrow(1:n_TRML_narrow)
        L_table(1:ntable) = l_TRML_narrow(1:n_TRML_narrow)

      case('TRML_wide')
        if(mype==0)&
        print *, 'TRML wide cooling'
        ntable = n_TRML_wide
        allocate(t_table(1:ntable))
        allocate(L_table(1:ntable))
        t_table(1:ntable) = t_TRML_wide(1:n_TRML_wide)
        L_table(1:ntable) = l_TRML_wide(1:n_TRML_wide)

      case default
        call mpistop("This coolingcurve is unknown")
      end select

      ! create cooling table(s) for use in amrvac
      fl%tcoolmax = t_table(ntable)
      fl%tcoolmin = t_table(1)
      ratt = (fl%tcoolmax-fl%tcoolmin)/(dble(fl%ncool-1) + smalldouble)

      fl%tcool(1) = fl%tcoolmin
      fl%Lcool(1) = L_table(1)

      fl%tcool(fl%ncool) = fl%tcoolmax
      fl%Lcool(fl%ncool) = L_table(ntable)

      do i=2,fl%ncool        ! loop to create one table
        fl%tcool(i) = fl%tcool(i-1)+ratt
        do j=1,ntable-1   ! loop to create one spot on a table
        ! Second order polynomial interpolation, except at the outer edge,
        ! or in case of a large jump.
          if(fl%tcool(i) < t_table(j+1)) then
            if(j.eq. ntable-1 )then
              fact1 = (fl%tcool(i)-t_table(j+1))     &
                    /(t_table(j)-t_table(j+1)) 
              fact2 = (fl%tcool(i)-t_table(j))       &
                    /(t_table(j+1)-t_table(j)) 
              fl%Lcool(i) = L_table(j)*fact1 + L_table(j+1)*fact2 
              exit
            else 
              dL1 = L_table(j+1)-L_table(j)
              dL2 = L_table(j+2)-L_table(j+1)
              jump =(max(dabs(dL1),dabs(dL2)) > 2*min(dabs(dL1),dabs(dL2)))
            end if
            if( jump ) then
              fact1 = (fl%tcool(i)-t_table(j+1))     &
                    /(t_table(j)-t_table(j+1)) 
              fact2 = (fl%tcool(i)-t_table(j))       &
                    /(t_table(j+1)-t_table(j)) 
              fl%Lcool(i) = L_table(j)*fact1 + L_table(j+1)*fact2
              exit          
            else
              fact1 = ((fl%tcool(i)-t_table(j+1))     &
                    * (fl%tcool(i)-t_table(j+2)))   &
                    / ((t_table(j)-t_table(j+1)) &
                    * (t_table(j)-t_table(j+2)))
              fact2 = ((fl%tcool(i)-t_table(j))       &
                    * (fl%tcool(i)-t_table(j+2)))   &
                    / ((t_table(j+1)-t_table(j)) &
                    * (t_table(j+1)-t_table(j+2)))
              fact3 = ((fl%tcool(i)-t_table(j))       &
                    * (fl%tcool(i)-t_table(j+1)))   &
                    / ((t_table(j+2)-t_table(j)) &
                    * (t_table(j+2)-t_table(j+1)))
              fl%Lcool(i) = L_table(j)*fact1 + L_table(j+1)*fact2 &
                        + L_table(j+2)*fact3
              exit
            end if
          end if
        end do  ! end loop to find create one spot on a table
      end do    ! end loop to create one table

      ! Go from logarithmic to actual values.
      fl%tcool(1:fl%ncool) = 10.0D0**fl%tcool(1:fl%ncool)
      fl%Lcool(1:fl%ncool) = 10.0D0**fl%Lcool(1:fl%ncool)

      ! Change unit of table if SI is used instead of cgs
      if (si_unit) fl%Lcool(1:fl%ncool) = fl%Lcool(1:fl%ncool) * 10.0d0**(-13)

      ! Scale both T and Lambda
      fl%tcool(1:fl%ncool) = fl%tcool(1:fl%ncool) / unit_temperature
      fl%Lcool(1:fl%ncool) = fl%Lcool(1:fl%ncool) * unit_numberdensity**2 * unit_time / unit_pressure * (1.d0+2.d0*He_abundance_rc) 

      fl%tcoolmin       = fl%tcool(1)+smalldouble  ! avoid pointless interpolation
      ! smaller value for lowest temperatures from cooling table and user's choice
      if (fl%tlow==bigdouble) fl%tlow=fl%tcoolmin
      fl%tcoolmax       = fl%tcool(fl%ncool)
      fl%lgtcoolmin = dlog10(fl%tcoolmin)
      fl%lgtcoolmax = dlog10(fl%tcoolmax)
      fl%lgstep = (fl%lgtcoolmax-fl%lgtcoolmin) * 1.d0 / (fl%ncool-1)

      deallocate(t_table)
      deallocate(L_table)

      if( fl%coolmethod == 'exact' ) then
        fl%tref = fl%tcoolmax
        fl%lref = fl%Lcool(fl%ncool)
        fl%Yc(fl%ncool) = zero
        do i=fl%ncool-1, 1, -1
            fl%Yc(i) = fl%Yc(i+1)
            do j=1,100
              tstep = 1.0d-2*(fl%tcool(i+1)-fl%tcool(i))
              call findL(fl%tcool(i+1)-j*tstep, Lstep, fl)
              fl%Yc(i) = fl%Yc(i) + fl%lref/fl%tref*tstep/Lstep
            end do
        end do
      end if

      rc_gamma_1=rc_gamma-1.d0
      invgam = 1.d0/rc_gamma_1
      

    contains

      subroutine rc_params_read(fl)

        use mod_global_parameters, only: unitpar,par_files
        use mod_constants, only: bigdouble
        type(rc_fluid), intent(inout) :: fl
        integer                      :: n
        integer :: ncool = 4000
        double precision :: cfrac=0.1d0
    
        !> Name of cooling curve
        character(len=std_len)  :: coolcurve='JCcorona'
    
        !> Name of cooling method
        character(len=std_len)  :: coolmethod='exact'
    
        !> Fixed temperature not lower than tlow
        logical    :: Tfix=.false.
    
        !> Lower limit of temperature
        double precision   :: tlow=bigdouble
    
        logical    :: rad_cut=.false.
        double precision :: rad_cut_hgt=0.5d0
        double precision :: rad_cut_dey=0.15d0

        namelist /rc_list/ coolcurve, coolmethod, ncool, cfrac, tlow, Tfix, rad_cut, rad_cut_hgt, rad_cut_dey

        do n = 1, size(par_files)
          open(unitpar, file=trim(par_files(n)), status="old")
          read(unitpar, rc_list, end=111)
  111       close(unitpar)
        end do

        fl%ncool=ncool
        fl%coolcurve=coolcurve
        fl%coolmethod=coolmethod
        if (coolmethod /= 'exact') call mpistop("Unknown cooling method: "//trim(coolmethod))
        fl%tlow=tlow
        fl%Tfix=Tfix
        fl%cfrac=cfrac
        fl%rad_cut=rad_cut
        fl%rad_cut_hgt=rad_cut_hgt
        fl%rad_cut_dey=rad_cut_dey

      end subroutine rc_params_read